SAMTRONIK SM-DH1100 Industrial Fume Extraction Unit
The SM-DH1100 is a Samtronik extraction unit. Check capture at the actual hood position before sizing the application from a catalogue airflow value.
SAMTRONIK SM-DH1100 Technical Specifications
| Published maximum flow | 1,200 m³/h in the supplier table. |
|---|---|
| Duct connection | 160 mm inlet and outlet. |
| Electrical | The model table lists 220 V AC, 50 Hz and 1,000 W. |
| Cabinet dimensions | The supplier table gives 600 × 500 × 1,180 mm. Allow clearance for the duct and filter service. |
| Pressure reference | The supplier lists an internal pressure figure of 2,800 Pa. Use a measured operating point for the installed hood and duct. |
Manufacturer model information
Model data describes the published configuration. Confirm fitted options, utilities and condition for the unit offered.
Configuration Must Be Verified
The SM-DH1100 is specified as an extraction unit with 160 mm connections. Verify the installed filter stack, duct resistance, exhaust arrangement and suitability for the identified process with the site safety team.
When SAMTRONIK SM-DH1100 Makes Sense — and When It May Not
Specify the source of the emissions, hood opening, duct length and bends. Confirm the filter media against the actual contaminants.
SAMTRONIK SM-DH1100 Acceptance Plan
Ask qualified personnel to measure capture at the work position with the proposed duct and loaded-filter condition.
- Identify the actual emissions and layout
Have the site team document the process, source location and duct route. Match the proposed filter and discharge arrangement to that assessment.
- Measure capture where it matters
Use an approved check at the working position with the proposed hood and duct. Record the measurement point, hood geometry and filter condition.
- Define a maintenance baseline
Retain pressure or airflow observations from the agreed setup. Decide what change triggers inspection of the filter, seals or duct before capture becomes ineffective.
Typical Applications for SAMTRONIK SM-DH1100
At a bench soldering station, check where smoke escapes as the board and operator change position. Use a hood position that preserves access without moving capture away from the source.
For a guarded process, check that duct length, bends and door openings are represented in the measurement. Confirm the agreed filter service condition before comparison.
Three SAMTRONIK SM-DH1100 Buyer Questions
What must the process handle?
Send the drawing, sample or material that defines the hardest job. Review the published maximum flow with that sample in view.
Which configuration is on offer?
Require the data plate and a configuration list with included items and separately priced options. Mark the setup used in the trial.
How will acceptance be measured?
Agree the result to keep from the trial and how it will be checked after transport. Include unresolved process limits on the order.
SAMTRONIK SM-DH1100 Running Video Review
Ask for a recording of the fitted unit and hood layout on the actual process if permitted. Show where capture was measured and include the test record rather than relying on the sound of the fan.
Request a dated recording tied to the offered machine's serial and tested sample. The preview opens the evidence request.
Inspection and Export Preparation for an Actual SAMTRONIK SM-DH1100
- Unit identityMatch the nameplate, electrical label and fitted options to the quotation. Keep any condition notes and missing accessories with that serial.
- Inspection and maintenanceInspect seals and filter condition and record the baseline pressure or flow used for service decisions.
- Acceptance recordRequest filter types, seal and duct configuration, supply voltage and the receiving site's discharge requirements. Record which site checks remain open at quotation.
- Export handoffAgree the transport state and the commissioning check. Request dated packing records for the actual unit before dispatch.
SAMTRONIK SM-DH1100 Spare Parts Scope
Quote the fitted prefilter, downstream media, seals, duct connections and other service items using the exact codes. Confirm media suitability and disposal procedures for the real contaminants.
Quotation checklist
Provide your application, sample details, destination utilities and required delivery scope. Ask the supplier to itemise configuration, service parts, installation and the evidence included with the offer.
Compare extraction as a line utility
The UNIX-DF404S is a point-soldering station. The SM-DH1100 addresses capture at a work point. Evaluate the tooling path and hood location together, while specifying solder-joint quality and ventilation acceptance separately.
Japan Unix UNIX-DF404S →FAQ
Common questions for overseas buyers evaluating a SAMTRONIK SM-DH1100.
Does the maximum flow establish capture?
Measure capture at the hood with the real duct path and filters. Obtain any required site ventilation assessment separately.
Is published filtration enough to select the unit?
Request documentation for the installed media and the intended emissions. Have the site team assess capture and discharge under the actual operating conditions.
What can cause lower capture after installation?
Check hood placement, air path, filters and seals against the measured baseline. Have qualified personnel investigate changes using the same measurement method.
Export Packing and Container Loading
Have qualified staff handle used filters before transport. Pack hood and duct components as identified items, and preserve the installed configuration and receiving-site checks.
These photos show general export preparation. Request dated protection and loading photos for the specific unit before dispatch.






Send Your SAMTRONIK SM-DH1100 Production Requirement
Share the process, representative job and required evidence. Ask for the fitted configuration and a quotation that distinguishes the machine, tooling, services and delivery.

